> For the complete documentation index, see [llms.txt](https://docs.enginsight.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.enginsight.com/docs/manual/english/platform-usage/observations/snmp/sensors/add-snmp-sensor.md). Agents can also search and read this documentation through its [MCP server](https://docs.enginsight.com/docs/~gitbook/mcp).

# Add SNMP Sensor

<i class="fa-computer-mouse">:computer-mouse:</i> Click <i class="fa-plus">:plus:</i> **Add SNMP Sensor** in the upper-right corner of the [Sensors Overview](https://docs.enginsight.com/docs/manual/english/platform-usage/observations/snmp/sensors.md#sensors-overview) to create a new SNMP sensor. The **Observations** → **SNMP** → **Add** view opens.

<i class="fa-computer-mouse">:computer-mouse:</i> After configuring all settings, click **Add SNMP Sensor** to save and create the new SNMP sensor.

{% hint style="danger" %}
**Please note**: If you leave this view without clicking **Add SNMP Sensor**, all configured settings will be lost and cannot be recovered.
{% endhint %}

***

## Settings

All settings for configuring your SNMP sensor are available on the left side.

The following options are available:

<table><thead><tr><th width="234.8984375">Option</th><th>Description</th></tr></thead><tbody><tr><td>Watchdog</td><td><p>Select the Watchdog that should monitor the corresponding network device.</p><div data-gb-custom-block data-tag="hint" data-style="danger" class="hint hint-danger"><p><strong>Please note</strong>: The Watchdog must be able to access the IP address of the network device.</p></div><p><i class="fa-computer-mouse">:computer-mouse:</i> Click the <strong>Watchdog</strong> field to expand a list of all available Watchdogs, and select a suitable Watchdog. Alternatively, use the free-text input to find Watchdogs in the list more quickly.<br><br>In addition to the Watchdog name, all subnets that the Watchdog can monitor are displayed.</p></td></tr><tr><td>IP Address</td><td>Enter the IP address of the network device to be monitored via SNMP.</td></tr><tr><td>Description</td><td><p>Provide a more detailed description of the SNMP sensor.</p><div data-gb-custom-block data-tag="hint" data-style="info" class="hint hint-info"><p>This field is optional.</p></div></td></tr><tr><td>Tags</td><td><p>Specify tags that can be used, for example, to assign the SNMP sensor to alarms.</p><div data-gb-custom-block data-tag="hint" data-style="info" class="hint hint-info"><p>The default tags are <strong>Observation</strong> and <strong>SNMP</strong>.</p></div><p><i class="fa-computer-mouse">:computer-mouse:</i> Click the <strong>Tags</strong> field to expand a list of all available tags, and select a suitable tag. Alternatively, use the free-text input to find tags in the list more quickly.<br><br>You can also create new tags.</p><p><i class="fa-computer-mouse">:computer-mouse:</i> Click the <strong>Tags</strong> field and enter a tag name of your choice. Press <strong>Enter</strong> to confirm your entry. Click the <strong>Remove</strong> icon <i class="fa-xmark">:xmark:</i> next to a tag to remove it from the <strong>Tags</strong> field.</p></td></tr><tr><td>SNMP Port</td><td><p>Enter the port number used by the network device for SNMP.</p><div data-gb-custom-block data-tag="hint" data-style="info" class="hint hint-info"><p>The default SNMP port is <strong>161</strong>.</p></div></td></tr><tr><td>SNMP Community</td><td><p><i class="fa-eye">:eye:</i> This field is only visible if you select <strong>SNMPv1</strong> or <strong>SNMPv2</strong> in the <strong>SNMP Version</strong> field.</p><div data-gb-custom-block data-tag="hint" data-style="danger" class="hint hint-danger"><p><strong>Please note</strong>: SNMPv1 and SNMPv2c do not use encryption and therefore pose a significant security risk. We recommend always using SNMPv3.</p></div><p>Enter the SNMP community string to be used to access the network device:<br></p><ul><li><strong>Public</strong>: The default read-only community string, which grants read-only permissions.</li><li><strong>Private</strong>: The default community string, which grants read and write permissions.</li></ul><div data-gb-custom-block data-tag="hint" data-style="info" class="hint hint-info"><p>The default SNMP community string is <strong>public</strong>.</p></div></td></tr><tr><td>SNMP Version</td><td><p>Select the SNMP version to use.</p><div data-gb-custom-block data-tag="hint" data-style="info" class="hint hint-info"><p>The default SNMP version is <strong>SNMPv2</strong>.</p></div><p><br><i class="fa-computer-mouse">:computer-mouse:</i> Click the <strong>SNMP Version</strong> field to expand a list of all available versions, and select an SNMP version.</p><p><br>The following options are available:</p><ul><li><strong>SNMPv1</strong>: The original version of SNMP, which uses the insecure community-string method.</li><li><strong>SNMPv2</strong>: An enhanced version of SNMPv1 that also uses the insecure SNMP community-string method.</li><li><strong>SNMPv3</strong>: The most secure version of the SNMP protocol, which uses encryption and authentication mechanisms.</li></ul><div data-gb-custom-block data-tag="hint" data-style="danger" class="hint hint-danger"><p><strong>Please note</strong>: SNMPv1 and SNMPv2c do not use encryption and therefore pose a significant security risk. We recommend always using SNMPv3.</p></div></td></tr><tr><td>Username</td><td><i class="fa-eye">:eye:</i> This field is only visible if you select <strong>SNMPv3</strong> in the <strong>SNMP Version</strong> field.<br><br>Enter the SNMPv3 username.</td></tr><tr><td>Privacy Passphrase</td><td><i class="fa-eye">:eye:</i> This field is only visible if you select <strong>SNMPv3</strong> in the <strong>SNMP Version</strong> field.<br><br>Enter the password used for SNMPv3 encryption.</td></tr><tr><td>Privacy Protocol</td><td><p><i class="fa-eye">:eye:</i> This field is only visible if you select <strong>SNMPv3</strong> in the <strong>SNMP Version</strong> field.<br><br>Select the encryption algorithm used to encrypt the transmitted data packets.<br><br><i class="fa-computer-mouse">:computer-mouse:</i> Click the <strong>Encryption Protocol</strong> field to expand a list of all available options, and select an encryption algorithm.</p><p>The following options are available:</p><ul><li><strong>NoPriv</strong>: The data packets are not encrypted.</li><li><strong>DES</strong>: The data packets are encrypted using the Data Encryption Standard (DES).</li><li><strong>AES</strong>: The data packets are encrypted using the Advanced Encryption Standard (AES).</li><li><strong>AES192</strong>: The data packets are encrypted using the Advanced Encryption Standard with a key length of 192 bits.</li><li><strong>AES256</strong>: The data packets are encrypted using the Advanced Encryption Standard with a key length of 256 bits.</li><li><strong>AES192C</strong>: The data packets are encrypted using the Advanced Encryption Standard with a key length of 192 bits when using Cisco devices.</li><li><strong>AES256C</strong>: The data packets are encrypted using the Advanced Encryption Standard with a key length of 256 bits when using Cisco devices.</li></ul></td></tr><tr><td>Authentication Passphrase</td><td><i class="fa-eye">:eye:</i> This field is only visible if you select <strong>SNMPv3</strong> in the <strong>SNMP Version</strong> field.<br><br>Enter the password used for SNMPv3 authentication.</td></tr><tr><td>Authentication Protocol</td><td><p><i class="fa-eye">:eye:</i> This field is only visible if you select <strong>SNMPv3</strong> in the <strong>SNMP Version</strong> field.<br><br>Select the authentication algorithm used to verify the integrity of the transmitted data packets.<br><br><i class="fa-computer-mouse">:computer-mouse:</i> Click the <strong>Authentication Protocol</strong> field to expand a list of all available options, and select an authentication algorithm.</p><p>The following options are available:</p><ul><li><strong>NoAuth</strong>: No authentication is performed.</li><li><strong>MD5</strong>: Message-Digest Algorithm 5 (MD5) is used for authentication.</li><li><strong>SHA</strong>: The Secure Hash Algorithm (SHA) is used for authentication.</li><li><strong>SHA224</strong>: The Secure Hash Algorithm with a key length of 224 bits is used for authentication.</li><li><strong>SHA256</strong>: The Secure Hash Algorithm with a key length of 256 bits is used for authentication.</li><li><strong>SHA384</strong>: The Secure Hash Algorithm with a key length of 384 bits is used for authentication.</li><li><strong>SHA512</strong>: The Secure Hash Algorithm with a key length of 512 bits is used for authentication.</li></ul></td></tr><tr><td>SNMP MIBs</td><td><p>Select one or more Management Information Base (MIB) files containing the metrics to be monitored on the network device. On the right side of the view, under <a href="#mib-file-test">Test Your MIBs</a>, you can test which metrics in the MIB files are supported by your network device.</p><div data-gb-custom-block data-tag="hint" data-style="info" class="hint hint-info"><p>Enginsight provides a wide range of standard MIB files based on the specifications of the Internet Assigned Numbers Authority (IANA) and the Internet Engineering Task Force (IETF). Contact the respective manufacturer to find out which of these MIB files can be used for a network device. You can also <a href="https://docs.enginsight.com/docs/manual/english/platform-usage/observations/snmp/custom-mibs.md#upload-mib">upload vendor-specific or custom MIB files to the Enginsight Platform</a>.</p></div><p><i class="fa-computer-mouse">:computer-mouse:</i> Click the <strong>SNMP MIBs</strong> field to expand a list of all available MIB files, and select one or more MIB files from the list. Click the <strong>Remove</strong> icon <i class="fa-xmark">:xmark:</i> next to an added MIB file to remove it from the <strong>SNMP MIBs</strong> field.</p></td></tr></tbody></table>

***

## MIB File: Test

On the right side of the view, you initially see an information text and the <i class="fa-magnifying-glass">:magnifying-glass:</i> **Test** button. The button remains disabled until you select a Management Information Base in the settings on the left.

<i class="fa-computer-mouse">:computer-mouse:</i> In the **SNMP MIBs** field on the left side of the view, select one or more MIB files to be used for monitoring the network device. Then click <i class="fa-magnifying-glass">:magnifying-glass:</i> **Test** to display a list of all primary metrics from the MIB file that the network device supports for monitoring.

### MIB File: Detail View

Each primary metric is initially displayed in a separate section. In the Object Identifier (OID) directory tree of a MIB file, these primary metrics are the parent nodes. The name of the primary metric and its additional description in English are displayed exactly as provided by the creator of the MIB file.

<i class="fa-computer-mouse">:computer-mouse:</i> Click **Expand** to display a list of all metrics subordinate to the respective primary metric in the form of their OIDs, along with additional options.

The MIB file detail view is displayed as a table. It provides the following information:

<table><thead><tr><th width="200.1328125">Column</th><th>Description</th></tr></thead><tbody><tr><td>Index</td><td>Displays the index number under which the corresponding metric is listed in the OID directory tree.</td></tr><tr><td>OID</td><td>Displays the unique identifier of the corresponding metric that can be monitored.</td></tr><tr><td>Thresholds</td><td><p>Specify whether thresholds should be defined for the corresponding metric and compared against the value actually measured.</p><p><i class="fa-computer-mouse">:computer-mouse:</i> Select the checkbox <i class="fa-square">:square:</i> next to <strong>Monitor Expected Value</strong> to enable threshold monitoring. Depending on the metric, additional fields open in which you can enter the corresponding values.<br><br>The following fields may be displayed:</p><ul><li><strong>Minimum</strong>: Enter a minimum value that should not be fallen below.</li><li><strong>Maximum</strong>: Enter a maximum value that should not be exceeded.</li></ul></td></tr></tbody></table>

***