> For the complete documentation index, see [llms.txt](https://docs.enginsight.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.enginsight.com/docs/knowledge-base/english/vendor-specific-guides/how-do-i-configure-syslog-notifications-for-the-enginsight-siem-in-eset-protect.md). Agents can also search and read this documentation through its [MCP server](https://docs.enginsight.com/docs/~gitbook/mcp).

# How do I configure Syslog notifications for the Enginsight SIEM in ESET PROTECT?

{% hint style="info" %}
This article applies to **older ESET PROTECT installations** in which individual notification templates still need to be configured manually for each event type.
{% endhint %}

***

To send logs from ESET PROTECT to the Enginsight SIEM, you need to create an event relay. This allows you to use the Enginsight agent Pulsar as a Syslog relay that receives Syslog data, processes it, and forwards it to the Enginsight SIEM.

In older ESET PROTECT installations, templates for each individual event type must be configured manually for sending Syslog notifications so that they can be processed and forwarded correctly by the host acting as the Syslog relay for Enginsight.

In the following article, we will show you how to create the corresponding notifications in ESET PROTECT Management and which templates you need.

{% hint style="warning" %}
**Please note**: The views and configuration steps described below may change. Enginsight assumes no liability for changes to third-party user interfaces.
{% endhint %}

***

Follow these steps to configure Syslog notifications for the Enginsight SIEM:

{% stepper %}
{% step %}
Log in to your ESET PROTECT instance.
{% endstep %}

{% step %}
Navigate to **More** → **Settings**.

1. Enable the toggle next to **Use Syslog server**.
2. In the **Host** field, enter the IP address of the host whose Pulsar is to be configured as the Event Relay for the Enginsight SIEM.

<figure><img src="https://2451436285-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2Fj1tpIYVLbDaeg6W04yHz%2Fuploads%2FHAY5G6fHhqDMi88jpDTf%2FEnginsight-KB-EN-ESET%20Event%20Relay-1.png?alt=media&amp;token=b2266168-ed4b-4e20-b7a2-1cc91b79d56e" alt=""><figcaption></figcaption></figure>
{% endstep %}

{% step %}
Scroll down to the **Logging** section.

1. Enable the toggle next to **Export logs to Syslog**.
2. In the **Format for exported logs** field, select **JSON**.
3. Click **Save**.
   {% endstep %}

{% step %}
You now need to configure **a separate Syslog template for each event type** so that events can be forwarded correctly to the Enginsight SIEM via the Event Relay.

1. Navigate to **Notifications** and create a new notification *for each event type*.
2. Give the new notification a meaningful display name.
3. Optionally assign a tag to the notification. We recommend that you use the tag *Enginsight*, for example, so you can find all configured notifications related to the Enginsight SIEM more quickly.
4. Enable the toggle next to **Enabled**.
5. Click **Next**.

<figure><img src="https://2451436285-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2Fj1tpIYVLbDaeg6W04yHz%2Fuploads%2Fyccr7yY0EhD62O6G6KAN%2FEnginsight-KB-EN-ESET%20Event%20Relay-3.jpg?alt=media&amp;token=17bb503e-b3e6-46da-9969-bea669028622" alt=""><figcaption></figcaption></figure>
{% endstep %}

{% step %}
You are now in the **Configuration** section.

1. In the **Category** field, select one event type *per notification*.
2. Click **Next**.

<figure><img src="https://2451436285-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2Fj1tpIYVLbDaeg6W04yHz%2Fuploads%2Fl3butiMb4vgxpDxuyKUS%2FEnginsight-KB-EN-ESET%20Event%20Relay-4.jpg?alt=media&amp;token=dd59cfab-2e75-418f-919f-924fe80514c5" alt=""><figcaption></figcaption></figure>
{% endstep %}

{% step %}
Navigate to the **Distribution** section.

1. Select the checkbox next to **Send Syslog**.

<figure><img src="https://2451436285-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2Fj1tpIYVLbDaeg6W04yHz%2Fuploads%2FrdHhDCvQiCSkVrhE20Ok%2FEnginsight-KB-EN-ESET%20Event%20Relay-5.jpg?alt=media&amp;token=18125031-c83d-4726-86db-4d3cb0e0e7b2" alt=""><figcaption></figcaption></figure>

2. In the **Content** field, enter the notification template that matches the *previously selected event type*.

The following notification templates are available:

<pre><code># Event Type: Scan

# Template:
<strong>4 - "${computer_name}"|"${severity}"|"${timestamp}"|"${scanned_targets}"|"${scanned}"|"${infected}"|"${cleaned}"|"${status}"|"${completion}"|"${scanner}"|"${user}"|"${computer_sg_parent}"|"${computer_sg_hierarchy}"|"${notification_name}"
</strong>

# Event Type: HIPS

# Template:
<strong>6 - "${computer_name}"|"${severity}"|"${timestamp}"|"${application}"|"${operation}"|"${target}"|"${action}"|"${rule_name}"|"${occurrences}"|"${user}"|"${computer_sg_parent}"|"${computer_sg_hierarchy}"|"${notification_name}"
</strong>

# Event Type: ESET INSPECT alert

# Template:
<strong>8 - "${computer_name}"|"${severity}"|"${timestamp}"|"${process_name}"|"${user}"|"${rule_name}"|"${occurrences}"|"${ei_console_link}"|"${hash}"|"${detection_handled}"|"${severity_score}"|"${computer_severity_score}"|"${computer_sg_parent}"|"${computer_sg_hierarchy}"|"${notification_name}"
</strong>

# Event Type: Firewall detection

# Template:
<strong>7 - "${computer_name}"|"${severity}"|"${timestamp}"|"${firewall_event}"|"${ip_address}"|"${src_address_type}"|"${src_port}"|"${tgt_address}"|"${tgt_address_type}"|"${tgt_port}"|"${protocol}"|"${inbound_comm}"|"${user}"|"${process_name}"|"${rule_name}"|"${detection_name}"|"${occurrences}"|"${detection_handled}"|"${computer_sg_parent}"|"${computer_sg_hierarchy}"|"${notification_name}"
</strong>

# Event Type: Computer identity recovered

# Template:
<strong>9 - "${timestamp}"|"${source_computer_name}"|"${target_computer_name}"|"${computer_sg_parent}"|"${computer_sg_hierarchy}"|"${notification_name}"
</strong>

# Event Type: Computer first connected

# Template:
<strong>10 - "${timestamp}"|"${computer_name}"|"${is_hardware_detection_enabled}"|"${computer_sg_parent}"|"${computer_sg_hierarchy}"|"${notification_name}"
</strong>

# Event Type: Antivirus detection

# Template:
<strong>1 - "${computer_name}"|"${severity}"|"${timestamp}"|"${detection_type}"|"${detection_name}"|"${scanner}"|"${virus_db}"|"${object_type}"|"${object_uri}"|"${action_performed}"|"${action_error}"|"${detection_handled}"|"${restart_required}"|"${user}"|"${process_name}"|"${circumstances}"|"${first_seen_time}"|"${hash}"|"${computer_sg_parent}"|"${computer_sg_hierarchy}"|"${notification_name}"
</strong>

# Event Type: Blocked File

# Template:
<strong>2 - "${computer_name}"|"${severity}"|"${timestamp}"|"${object_uri}"|"${description}"|"${cause}"|"${action}"|"${process_name}"|"${user}"|"${hash}"|"${first_seen_time}"|"${detection_handled}"|"${computer_sg_parent}"|"${computer_sg_hierarchy}"|"${notification_name}"
</strong>

# Event Type: Computer cloning question created

# Template:
<strong>3 - "${timestamp}"|"${source_computer_name}"|"${target_computer_name}"|"${computer_sg_parent}"|"${computer_sg_hierarchy}"|"${notification_name}"
</strong>

# Event Type: New MSP customer found

# Template:
<strong>5 - "${timestamp}"|"${msp_customer_name}"|"${msp_company_name}"|"${notification_name}"
</strong></code></pre>

3. Click **Finish** to save the notification template.
   {% endstep %}
   {% endstepper %}

***